Achieve an Economy of Scale
Increase productivity and efficiency with automated, cost-effective and easy-to-use workflows for next-generation sequencing (NGS) library preparation, gene expression analysis and genotyping by allele-specific PCR.
Using Juno™ you can produce dozens to hundreds of sample libraries daily for hypothesis-free RNA-seq or targeted DNA NGS. Optimized for use with Illumina® sequencing systems in combination with Fluidigm supplied sample barcodes, Juno enables accurate sequencing of more samples—faster and more affordably than ever before.
Juno also serves as a universal controller to prepare integrated fluidic circuits (IFCs) for both gene expression and genotyping analysis when used together with the Fluidigm Biomark™ HD system. While providing significant advantages in sample throughput for the analysis of dozens to hundreds of DNA variants or RNA transcripts per sample, the Juno system also significantly reduces reaction volumes and required hands-on time, resulting in substantial savings over traditional methods.
Efficient
Reduce costs with nanoliter-scale reaction volumes and walkaway automation.
|
Flexible
Perform NGS library preparation or pair with a Biomark HD to implement genotyping, sample identification, gene expression and copy number variant analysis and digital PCR.
|
Scalable
Deliver reproducible results day after day using robust microfluidic automation that you can rely on.
|
Proven
Easily design assay panels for targeted NGS, SNP genotyping or gene expression to detect DNA variants, mRNAs or miRNAs—from a few targets to several thousand.
|
Technology
Juno integrates IFC control and thermal cycling to enable scalable, automated NGS library preparation for Illumina sequencers and IFC preparation for gene expression, genotyping and digital PCR applications using the Fluidigm Biomark HD.
Workflow
- Transfer
- Run
- Sequence
Transfer
NGS Library Preparation Workflow
Dispense the purified DNA, sample barcodes, PCR primers and master mix into designated inlets on the IFC before placing it onto the Juno loading tray.
Run
NGS Library Preparation Workflow
Press Start. Juno automatically mixes nanoscale reactions within the IFC to amplify DNA targets and barcode sample libraries.
Sequence
NGS Library Preparation Workflow
Targeted DNA sequencing libraries are collected from the IFC, and adapter PCR and cleanup are performed in a single tube reaction, followed by sequencing on an Illumina system.
- Transfer
- Run
- Read
Transfer
SNP Genotyping Workflow
Dispense the purified DNA, sample barcodes, SNP Type™ or probe-based assays and master mix into designated inlets on the IFC before placing it onto the Juno loading tray.
Run
SNP Genotyping Workflow
Press Start. Juno automatically mixes nanoscale PCR reactions within the IFC and performs amplification using the integrated thermocycler. For compatibility with low sample inputs down to 5.5 ng, the option for a low-cycle-number preamplification exists. This option is fully integrated and automated on the IFC.
Read
SNP Genotyping Workflow
Transfer the IFC with completed SNP reactions to the Biomark HD or EP1™ for endpoint genotyping analysis.
- Transfer
- Load
- Run | Read
Transfer
Gene Expression Workflow
Dispense purified cDNA from RNA or miRNAs, qPCR assays and master mix into designated inlets on the IFC before placing it onto the Juno loading tray.
Load
Gene Expression Workflow
Press Start. Juno automatically loads the IFC with input sample, assays and reagents to prepare for thousands of nanoscale real-time PCR reactions.
Run | Read
Gene Expression Workflow
Transfer the IFC with pre-mixed real-time PCR reactions to the Biomark HD for amplification and real-time quantitative detection.
Support
Juno Support
Click the link below to view training tutorials, browse FAQs, read technical documents, review service plans and locate the right IFCs, kits and reagents for your research. If you still need help, reach out to one of our support specialists here.
components
IFCs, Assays and Reagents
Juno Targeted Sequencing IFC
Prepare targeted DNA sequencing libraries with maximum efficiency in batch sizes that match your throughput needs. The LP 48.48 and LP 192.24 IFCs provide multiple formats for targeted DNA sequencing library preparation.
Juno Genotyping IFC
Analyze up to 96 DNA samples (9,216 datapoints) simultaneously across 96 different SNP Type or probe-based assays with the Juno 96.96 Genotyping IFC.
Dynamic Array IFCs
Experience a new level of efficiency and throughput for gene expression and genotyping applications with the Fluidigm Dynamic Array™ IFCs used together with the Juno and Biomark HD systems.
SNP Type Assays
SNP Type™ assays provide a high-throughput, low-cost single-nucleotide polymorphism (SNP) genotyping solution enabling rapid assay design for efficient variant screening. The assays are based on allele-specific PCR SNP detection chemistry and are available for use with Fluidigm IFC technology on Biomark HD, EP1™ and Juno™ systems.
SNP Trace™ Panel
Ensure accurate sample identification with an authoritative panel of 96 SNPs that determine specific attributes around gender, ancestry or polymorphism across populations using the SNP Trace Panel™.
Targeted DNA Sequencing Library Kit
- Juno Targeted Sequencing IFC
- Juno Genotyping IFC
- Dynamic Array IFCs
- SNP Type Assays
- SNP Trace™ Panel
- Targeted DNA Sequencing Library Kit
Related Systems
Juno

Increase productivity and efficiency with automated cost-effective and easy-to-use workflows for DNA and RNA next-generation sequencing (NGS) library preparation.
Biomark HD

Analyze gene expression with real-time PCR, industry-leading flexibility and consistently high-quality results on the
Biomark™ HD system.
Polaris

Seamlessly integrate cell biology and molecular analysis at the single-cell level. Within one workflow
Polaris™ processes single cells for mRNA sequencing applications.
EP1

The EP1™ endpoint system provides efficient and economical endpoint PCR detection downstream of the Juno™ system.
- Juno
- Biomark HD
- Polaris
- EP1
Software
Advanta RNA-Seq Library Normalization Workbook V C3
This custom Microsoft® Excel® workbook is designed for use with the Advanta™ RNA-Seq NGS Library Prep Kit and Advanta RNA-Seq XT NGS Library Prep Kits with the Juno™ system to automate calculations and tracking of volume adjustment requirements of sample libraries prior to pooling.
Juno Software
Juno Software v3.14.1, updated September 6, 2019
Download the most up-to-date software version 3.14.1 to enable running hypothesis-free RNA-seq and targeted DNA NGS library prep applications.
- Advanta RNA-Seq Library Normalization Workbook V C3
- Juno Software
Specifications
Instrument
Thermal control |
Peltier-based, ranging from 4 °C to 99 °C
Maximum heating rate: >4 °C/sec
Maximum cooling rate: >3 °C/sec |
Depth |
69.8 cm (27.5 in) |
Width |
43.9 cm (17.3 in) |
Height |
50 cm (19.7 in) |
Weight |
52 kg (115 lb) |
Voltage |
100–240 V AC |
Frequency |
50–60 Hz |
Maximum current |
8.0 A |
Typical average power consumption |
Idle: 40 W
Operating: 175 W |
Data Storage
Ethernet connection |
1 GB/sec |
Hard drive |
40 GB |
Port |
USB port |
Computer |
Internal CPU with touchscreen interface |
Software
System |
Juno™ software v3.9.1 or later |
Work Environment (indoor use only)
Minimum rear clearance |
10 cm (4 in) |
Minimum front clearance |
25 cm (10 in) |
Ambient temperature |
15–28 ºC (59–82 ºF) |
Humidity |
20–80%, noncondensing |
Pollution degree |
2 |
Electrical installation |
Category II |
Altitude |
Up to 2,000 m (6,562 ft) |
IFC Compatibility
Genotyping |
Juno 96.96 GT IFC
96.96 GT IFC
48.48 GT IFC
192.24 GT IFC
Flex Six™ GT IFC
|
Gene Expression |
96.96 GE IFC
48.48 GE IFC
192.24 GE IFC
24.192 GE IFC
Flex Six GE IFC
|
Digital PCR |
12.765 dPCR IFC
48.770 dPCR IFC
qdPCR 37K™ IFC
|
Targeted Sequencing |
LP 48.48 IFC
LP 192.24 IFC
|